產品資訊
- VGA cables can be made with 3 analog cables with 6 signal cables
- VGA cables compatible with IBM VGA, sVGA, VESA, etc
- Tinned conductors at the bare end installation of a 15-pin HD connector
- For typical 5 BNC installation, just cut and prep the coaxes as usual for crimp or compression connectors on 26/28 gauge mini coax
- Multicore conductors, Thermoplastic insulation
- 100% Shielding against EMI via full coverage of Aluminium Foil Tape and Braid Wires
技術規格
General
| Conductors |
Stranded Tinned Copper (7 x 0.12mm TC) + 27 x 0.1mm Tinned Copper Drain |
Stranded Tinned Copper (7 x 0.12mm TC) |
|
| Insulation |
3 core insulation |
6 core insulation |
|
| Shielding | Primary | Aluminium Foil Tape 100% overlap the conductors and insulation | |
| Secondary | Aluminium Magnesium Braid | ||
| Jacket | 80C Degree Heat Resistant PVC jacket | ||
| Overall Diameter | 8.35 mm +/-5% | ||
Return Loss
| Frequency MHz | 0-50MHz | >25 dB | |
| 50-600MHz | >20 dB | ||
| 600-900MHz | >15 dB |
Mechanical Characteristics
| Tensile Strength (Mpa) | ≥13.8 | ||
| Insulation Elongation | ≥80% | ||
| Minimum Bending Radius | Storage | 8 x OD | |
| Use | 10 x OD | ||
| Operation Temperature | -20°C ~ +70°C | ||
| Spark Test | 3.0KV/ Sec NO BREAKING | ||
| Cold Bend Test | - 10±1°C/4HR NO CRACKING | ||
| Heat Shock Test | 121±1°C/1HR NO CRACKING |
Electrical Characteristics
| Frequency MHz | 1 | 5 | 10 | 50 | 100 | 180 | 400 | 750 | 1000 |
| Attenuation dB / 100 ft | -0.6 | -1.4 | -2.1 | -4.7 | -6.8 | -9.2 | -14.2 | -20.1 | -23.8 |
| Capacitance: 18.3pF per ft, 60pF per meter | |||||||||
| DC Resistance: 72.2Ω per 1000 ft, 237Ω per km | |||||||||
| Impedance: 75Ω (±5Ω) | |||||||||
| Temperature: - 20°C ~ 80°C | |||||||||
| Velocity of propogation : 78% | |||||||||
Construction